| Sign In | Join Free | My bjjsgy.com | 
 | 
Brand Name : Huaying
Model Number : HYVA-405
Certification : ISO/CE
Place of Origin : Wuhan
MOQ : 1
Price : Negotiable
Supply Ability : 10 units per week
Packaging Details : Wooden case
Warranty : 1 year free and lifelong maintenance
Typical error : 0.02%
Storage : 8G
Function : CT and PT On-site calibration
Customize service : Provided
Feature : Portable
Portable CT PT transformer Test Set For Transformation Ratio Polarity Gauss
Product name: CT PT Analyzer HYVA-405
Reference Standard
GB 1207-2006, GB 1208-2006 (IEC 60044-1), GB16847-1997 (IEC 60044-6) , IEEE C57.13-1993
HYVA-405 is mainly used to detect on phase error, ratio error, burden and admittance test of CT&PT. In addition, it supports data save and site printing, this can not only omit a lot of troublesome work such as manual voltage regulating, manual record and curve tracing, but also dump testing data through USB interface with USB disk .
Features
★ Wide range, it can do CT test from 50/5 zero-sequence CT to 35000/1 generator CT.
★ Simple operation, all parameters and projects of the transformer are tested with one click
★ Ultra-high measurement precision, Typical ratio measurement error is only 0.02%
★ With powerful data management function, single machine can store more than 5000 groups data.
★ Intelligent assessment, it makes conclusion automatically whether the transformer test is qualified.
★ Strong application software support, make word reports for test result in bulk
★ Complete transformer on-site calibration without standard transformer, strong current power source, and load-box
Technical Parameters:
| 1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 2 Power supply: AC220V±10%, 50/60Hz±10% 3 Voltage output: 0.1~180V (AC) 4 Current output: 0.001~5A(RMS) 5 Power output: 500VA 6 Maximum knee voltage measurement: 45KV 7 Current measurement: Range: 0~10A (automatically change range in 0.1/0.4/2/10A) Error: <±0.1%+0.01%FS 8 Voltage measurement: Range: 0~200V (automatically change range in 1V/10V/70V/200V) Error: < ±0.1%+0.01%FS 9 Turns ratio measurement: Range:1~35000 1~2000 error<0.05% 2000~5000 error<0.1% 5000~35000 error<0.2% 10 Phase measurement: error: ±2min; resolution: 0.01min 11 Winding resistance measurement: Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) Error: < 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ 12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree | 13 CT Secondary burden: Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) Error: <0.2%RDG+0.02%FS Maximum resolution: 0.001ohm 14 PT Secondary burden: Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) Error :<0.2%RDG+0.02%FS Maximum resolution: 0.1ohm 15 PT ratio measurement: Range: 1~35000 1~10000 error<0.1% 10000~35000 error<0.2% 16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1% 17 PT phase angle measurement: maximum error < 3min 18 Make evaluation for test results according to selected standards 19 Make word report for test result 20 Make word reports one time for multi-group test records on the PC 21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test 22 Compare excitation curves with saved excitation curves in the same window 23 Memory capacity: >1000 groups test results 24 Working condition: temperature: -10℃~50℃; moist: ≤90% | 
|   | 
| Portable CT PT transformer Test Set For Transformation Ratio Polarity Gauss Images | 
 Durable CT PT Test Set Easy Operation With Rs232 Communication Interface
                                                                                    
                        
                        
                        
                                                            Durable CT PT Test Set Easy Operation With Rs232 Communication Interface
                                                    
                        
                     Full Automatic CT PTTesting Equipment With High Performance CPU Easy Operation
                                                                                    
                        
                        
                        
                                                            Full Automatic CT PTTesting Equipment With High Performance CPU Easy Operation
                                                    
                        
                     8G Portable CT PT Test Set High Accuracy Strong Data Management Simple Operation
                                                                                    
                        
                        
                        
                                                            8G Portable CT PT Test Set High Accuracy Strong Data Management Simple Operation
                                                    
                        
                     High Performance CT PT Test Set Measure Volt Ampere Characteristic / Polarity
                                                                                    
                        
                        
                        
                                                            High Performance CT PT Test Set Measure Volt Ampere Characteristic / Polarity
                                                    
                        
                     220V 50Hz Current Transformer Test Set For Testing Turn Ratio , Excitation
                                                                                    
                        
                        
                        
                                                            220V 50Hz Current Transformer Test Set For Testing Turn Ratio , Excitation
                                                    
                        
                     500 VA Field Testing CT PT Test Set Portable With Trolley Case CE Certificated
                                                                                    
                        
                        
                        
                                                            500 VA Field Testing CT PT Test Set Portable With Trolley Case CE Certificated
                                                    
                        
                     High Precision Current Transformer Testing Equipments CT PT Set ISO Approve
                                                                                    
                        
                        
                        
                                                            High Precision Current Transformer Testing Equipments CT PT Set ISO Approve
                                                    
                        
                     High Precision Current Transformer Testing Equipments CT PT Set ISO Approve
                                                                                    
                        
                        
                        
                                                            High Precision Current Transformer Testing Equipments CT PT Set ISO Approve
                                                    
                        
                     Multi Function CT PT Test Set CT PT Analyzer High Accuracy 500 VA 15 Kg Weight
                                                                                    
                        
                        
                        
                                                            Multi Function CT PT Test Set CT PT Analyzer High Accuracy 500 VA 15 Kg Weight
                                                    
                        
                     Professional Automatic CT PT Test Set Built In Industrial PC Run Like Computer
                                                                                    
                        
                        
                        
                                                            Professional Automatic CT PT Test Set Built In Industrial PC Run Like Computer